AGI Graphics

Processors At Tower Polymer

  • 9-channel computer that even simultaneously controls all processing steps: Pre-exposure time / Main exposure time, UVC exposure time, Development temperature, Post exposure time, Development time, Dryer temperature, Time of dryer (one time for each drawer)
  • The showcase is equipped with a suction plan that, thanks to the high number of lamps, guarantees a uniform coverage
  • Cleaning of the polymer in the stainless steel tank is via the orbital movement of the polymer plate plate (foldable in model A1) and a height-adjustable brush module
  • The anti-tack compartments (A4, A3 and A2 models) and anti-tack post-exposure (for A1 format) are totally stainless steel and have a suction separate from that of the washbasin and the compartment dryer
  • Lamp counters for each lamp group

Processors at Tower Polymer

Specifications

A4/S A3/S A2/S A1/S
Max Sheet Size (mm) 270×370 370x520 530x760 710x890
Max Sheet Size (inches) 10"x14" 14"x20" 20"x29" 27"x35"
Lamps esp. GRAPES 10x24W
10R L.437
9x40W
10R L.590
12x60W
10R L.900
15x60W
10R L.1200
UVC lamps 5x15W
L.437
10x15W
L.437
12x30W
L.900
13x36W
L.1200
Lamapde post.esp. GRAPES - - - 14x60W
10R L.1200
Stainless steel tank (liters) 20 27 50 110
Power (kw) 3.5 3.5 7.5 8.5
Resistance (W) 600 600 3x600 4x600
Power 230V 50/60Hz
(1PH+N+GND)
230V (3PH+GND) 60Hz
400V (3PH+N+GND) 50Hz
Dimensions (LxWxH) (cm) 57x76x120 77x101x120 106x108x120 145x140x135
Weight kg) 150 200 310 520